-
+Home page
-
+GENERATING SETS / GENERATORS
-
+LIGHTING SYSTEMS
-
+WELDING SETS
- ALTERNATORS
-
+CHARGERS AND UPS
-
+INVERTER / TRANSFORMERS / VOLTAGE REGULATORS
-
+CLIMATE CONTROL
-
+PUMPS AND TANKS
-
+GARDEN - AGRI
- ENGINES
- OUTBOARD MOTORS
-
+PALLET TRUCKS AND FORKLIFT TRUCKS
-
+COMPRESSORS / PAINTERS / HIGH-PRESSURE CLEANERS
-
+PRODUCTS FOR VEHICLES AND BOATS
- SOLAR AND PHOTOVOLTAIC PANELS
- WATERMAKERS FOR LAND FACILITIES
- CHARGING STATIONS
-
+PIPES / SILENCERS / FITTINGS
- MARINE ENGINES
-
+CAMPING
-
+ACCESSORIES / SPARE PARTS
- FOR ENGINES AND OUTBOARDS
- FOR GENERATING SETS
- FOR ALTERNATORS
- FOR UPS
- FOR WELDERS
- FOR MOTOR PUMPS ELECTRIC PUMPS
- FOR HAND PUMPS
- FOR TANKS AND RESERVOIRS
- FOR COMPRESSORS
- FOR ROAD MARKING MACHINES
- FOR PAINTING PUMPS
- FOR PLASMA CUTTERS
- FOR PALLET TRUCKS AND FORKLIFTS
- FOR GENERATORS FOR CAMPERS
- FOR REFRIGERATORS
- FOR SATELLITE ANTENNAS
- FOR HEAT GENERATORS
- FOR TRAVEL AIR CONDITIONERS
- FOR MARINE GENERATING SETS
- FOR BRUSHCUTTERS AND VERSATOOL
- FOR LAWNMOWERS
- FOR RIDE-ON LAWNMOWERS
- FOR TILLERS
- FOR SNOWTHROWERS
- FOR LIGHTING TOWERS
- USED PRODUCTS
- ACQUISTO
-
+RENTAL
-
+BRANDS
-
+DOMETIC
-
+GENSET
-
+GREEN POWER
-
+HONDA
-
+MASE
-
+MOSA
-
+PRAMAC
-
+WFM
-
+POWERMATE
-
+VOLPI TECNO ENERGIA
-
+TECNOGEN
-
+COELMO
-
+AMA
-
+TELAIR
-
+HYUNDAI
-
+VINCO
-
+BINDA
-
+ELETRAS
-
+BELTRAME
-
+FINI
-
+NANNI
-
+IDROFOGLIA
-
+GENERAC
-
+GMP S.p.A.
-
+LIFTER
-
+LUXTOWER
-
+CGM
-
+AGROWATT
-
+CAT CATERPILLAR
-
+BIEMMEDUE
-
+ELC
-
+DYNAMICA
-
+OMMCItalflex Srl
-
+SINCRO
-
+TESSARI
-
+HELVI
-
+MECC ALTE
-
+LARIUS
-
+SCHENKER
-
+GENMAC
-
+TELWIN
-
+LINZ ELECTRIC
-
+EFOY COMFORT
-
+ITALTOWER
-
+FISCHER PANDA
-
+KOHLER
-
+ENDRESS
-
+AIRSTAR
-
+LOMBARDINI
-
+CUMMINS ONAN
-
+TRUMA
-
+ZIPWAKE
-
+ENERGY
-
+VICTRON Energy
-
+MENNEKES
-
+SAF-FRO
-
+NSM
-
+VISA
-
+SCANGRIP
-
+ICOEM S.r.l.
-
+SiFi
-
+MECLUBE
-
+REVELLO
-
+VILLAGE MARINE
-
+IDROMAR
-
+WESTERN CO
-
+VITRIFRIGO
-
+WEBASTO
-
+CLIMMA
-
+MARELLI MOTORI
-
+EGM
-
+ASTURO
- FILIPPINI Generating Sets
-
+MOSCATELLI
-
+BA.M.E.
-
+BERTOLI POWER UNITS
-
+PowerMeter
-
+IRONSYSTEM
-
+Underwater Lights Limited
-
+PREMIUM POWER
-
+VETUS
-
+NO BRAND
-
+ECO GREEN SYSTEM
-
+BLACK+DECKER
-
+WHISPER
-
+OFF BY INDEL B
-
+Pedrollo group
- HIGH PRESSURE WATERMAKERS
- AIRSTAR
-
+VARMATEC
-
+FASTVERDINI
-
+MCH
-
+RAYWIN
-
+BADA
-
+EMACH
-
+UNIMEC
-
+Remigo
-
+Osmosea
-
+AUTOCLIMA
-
+NDS ENERGY
-
+AIRXCEL
-
+Ciclone S.r.l.
-
+ATLAS COPCO
-
+ACER
-
+EMILIANA SERBATOI
-
+OREFICE
-
-
+BESS BATTERY ENERGY STORAGE SYSTEMS
-
-
+RENTAL
- Maintenance
- All manufacturers
- Contatti
HEAT GENERATORS
....-
CATEGORIES
-
- GENERATING SETS / GENERATORS
- LIGHTING SYSTEMS
- WELDING SETS
- ALTERNATORS
- CHARGERS AND UPS
- INVERTER / TRANSFORMERS / VOLTAGE REGULATORS
- CLIMATE CONTROL
- PUMPS AND TANKS
- GARDEN - AGRI
- ENGINES
- OUTBOARD MOTORS
- PALLET TRUCKS AND FORKLIFT TRUCKS
- COMPRESSORS / PAINTERS / HIGH-PRESSURE CLEANERS
- PRODUCTS FOR VEHICLES AND BOATS
- SOLAR AND PHOTOVOLTAIC PANELS
- WATERMAKERS FOR LAND FACILITIES
- CHARGING STATIONS
- PIPES / SILENCERS / FITTINGS
- MARINE ENGINES
- CAMPING
- ACCESSORIES / SPARE PARTS
- FOR ENGINES AND OUTBOARDS
- FOR GENERATING SETS
- FOR ALTERNATORS
- FOR UPS
- FOR WELDERS
- FOR MOTOR PUMPS ELECTRIC PUMPS
- FOR HAND PUMPS
- FOR TANKS AND RESERVOIRS
- FOR COMPRESSORS
- FOR ROAD MARKING MACHINES
- FOR PAINTING PUMPS
- FOR PLASMA CUTTERS
- FOR PALLET TRUCKS AND FORKLIFTS
- FOR GENERATORS FOR CAMPERS
- FOR REFRIGERATORS
- FOR SATELLITE ANTENNAS
- FOR HEAT GENERATORS
- FOR TRAVEL AIR CONDITIONERS
- FOR MARINE GENERATING SETS
- FOR BRUSHCUTTERS AND VERSATOOL
- FOR LAWNMOWERS
- FOR RIDE-ON LAWNMOWERS
- FOR TILLERS
- FOR SNOWTHROWERS
- FOR LIGHTING TOWERS
- USED PRODUCTS
- BRANDS
- DOMETIC
- GENSET
- GREEN POWER
- HONDA
- MASE
- MOSA
- PRAMAC
- WFM
- POWERMATE
- VOLPI TECNO ENERGIA
- TECNOGEN
- COELMO
- AMA
- TELAIR
- HYUNDAI
- VINCO
- BINDA
- ELETRAS
- BELTRAME
- FINI
- NANNI
- IDROFOGLIA
- GENERAC
- GMP S.p.A.
- LIFTER
- LUXTOWER
- CGM
- AGROWATT
- CAT CATERPILLAR
- BIEMMEDUE
- ELC
- DYNAMICA
- OMMCItalflex Srl
- SINCRO
- TESSARI
- HELVI
- MECC ALTE
- LARIUS
- SCHENKER
- GENMAC
- TELWIN
- LINZ ELECTRIC
- EFOY COMFORT
- ITALTOWER
- FISCHER PANDA
- KOHLER
- ENDRESS
- AIRSTAR
- LOMBARDINI
- CUMMINS ONAN
- TRUMA
- ZIPWAKE
- ENERGY
- VICTRON Energy
- MENNEKES
- SAF-FRO
- NSM
- VISA
- SCANGRIP
- ICOEM S.r.l.
- SiFi
- MECLUBE
- REVELLO
- VILLAGE MARINE
- IDROMAR
- WESTERN CO
- VITRIFRIGO
- WEBASTO
- CLIMMA
- MARELLI MOTORI
- EGM
- ASTURO
- FILIPPINI Generating Sets
- MOSCATELLI
- BA.M.E.
- BERTOLI POWER UNITS
- PowerMeter
- IRONSYSTEM
- Underwater Lights Limited
- PREMIUM POWER
- VETUS
- NO BRAND
- ECO GREEN SYSTEM
- BLACK+DECKER
- WHISPER
- OFF BY INDEL B
- Pedrollo group
- HIGH PRESSURE WATERMAKERS
- AIRSTAR
- VARMATEC
- FASTVERDINI
- MCH
- RAYWIN
- BADA
- EMACH
- UNIMEC
- Remigo
- Osmosea
- AUTOCLIMA
- NDS ENERGY
- AIRXCEL
- Ciclone S.r.l.
- ATLAS COPCO
- ACER
- EMILIANA SERBATOI
- OREFICE
- DOMETIC
- BESS BATTERY ENERGY STORAGE SYSTEMS
- GENERATING SETS / GENERATORS
-
Heat generators
Construction and events
This family includes mobile hot air generators that comply with the logic of mobile or temporary emergency heating, both indoors and outdoors, at a relatively low price and, above all, without the need for installation. Thanks to their manoeuvrability, mobility, sturdiness, reliability and flexibility, they are mainly used in the building sector (construction sites, constructions, etc...) and in temporary structures or shelters (tents, tensile structures, etc...). These are generally single-fuel products (diesel or gas), equipped with wheels and/or handles that can be equipped with various accessories that allow different applications depending on customer needs.
Agriculture and livestock
This family includes mobile hot air generators dedicated to applications in agriculture and breeding. They solve several problems of heating of structures where the economy of the investment is decisive, such as greenhouses and farms. These products are generally equipped with hooks or brackets for installation suspended from the ceiling and/or with a base for installation on the ground on supporting bases. They can have an integrated or separate burner. For the former, applications in dusty, dirty and oxygen-free environments are not recommended, while the latter are suitable in such environments provided that a sheath is connected to the burner through a snorkel socket for the intake of clean air from outside.
Industry
This family includes hot air generators that cannot be considered totally mobile and emergency because they all require limited ancillary works for their installation. They are normally used in traditional heating (warehouses, warehouses, laboratories, factories, etc. ...) and, thanks to the cost-effectiveness of the investment, are an alternative proposal to conventional heating systems. These products have a vertical structure and all have indirect combustion: they use a heat exchanger that allows the extraction of fumes through a chimney that can be connected to the outside; they can therefore be placed inside closed rooms; on the other hand, they have an efficiency of around 90%, as they have to be calculated, reducing the amount of heat evacuated through the chimney.
BM2 SCUDO 235T HOT AIR GENERATOR (OIL-GAS)
- Phase
- Three phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Rated heat power
- 235.72 KW - 202715 Kcal/h - 810861 BTU/h
- Output heat power
- 227.47 KW - 195620 Kcal/h - 782480 BTU/h
- Heat efficiency (%)
- 96.5
- Air flow (m³/h)
- 20000
- Available static press
- 500 Pa - 50 mm H₂O
- Termperature rise at 20°C (°C)
- 47
- Effective heat range (m)
- 70
- Oil consumption (Kg/h)
- 18.65
- Natural Gas consumption (m³/h)
- 22.035
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 8.637 - 16.92
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 4970
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 50
- Ø outlet hose - L.max 2 ways (mm - m)
- 600 - 30
- Ø outlet hose - L.max 4 ways (mm - m)
- 400 - 25
- Ø outlet snorkel - L.max (mm - m)
- 150 - 6
- Ø inlet hose - L.max (mm - m)
- 750 - 10
- Length (mm)
- 2790
- Width (mm)
- 900
- Height (mm)
- 1766
- Dry weight (Kg)
- 856
BM2 TITAN 235T HOT AIR GENERATOR (OIL-GAS)
- Phase
- Three phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Rated heat power
- 235.72 KW - 202715 Kcal/h - 810861 BTU/h
- Output heat power
- 227.47 KW - 195620 Kcal/h - 782480 BTU/h
- Heat efficiency (%)
- 96.5
- Air flow (m³/h)
- 20000
- Available static press
- 500 Pa - 50 mm H₂O
- Termperature rise at 20°C (°C)
- 47
- Effective heat range (m)
- 70
- Oil consumption (Kg/h)
- 18.65
- Natural Gas consumption (m³/h)
- 22.035
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 8.637 - 16.92
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 4970
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 50
- Ø outlet hose - L.max 2 ways (mm - m)
- 600 - 30
- Ø outlet hose - L.max 4 ways (mm - m)
- 400 - 25
- Ø outlet snorkel - L.max (mm - m)
- 150 - 6
- Ø inlet hose - L.max (mm - m)
- 750 - 10
- Length (mm)
- 2630
- Width (mm)
- 1042
- Height (mm)
- 1840
- Dry weight (Kg)
- 535
BM2 TITAN 235T HOT AIR GENERATOR (OIL-GAS)
FANTASTIC AIR-WATER HEAT PUMP EVI DC R32 THREE-PHASE 42KW INVERTER
- Phase
- Three phase
- Frequency (Hz)
- 50
- Voltage (V)
- 380
- Operating temperature (°C)
- -15~43
- Refrigerating yield
- 30 KW
- Heating power
- 42 KW
- Acoustic pressure
- 55 dB(A)
- Length (mm)
- 1380
- Width (mm)
- 515
- Height (mm)
- 1585
- Dry weight (Kg)
- 195
- Coolant
- R32/R410a
FANTASTIC AIR-WATER HEAT PUMP EVI DC R32 THREE-PHASE 42KW INVERTER
BM2 FORCED AIR SPACE HEATERS JUMBO 235M (OIL-GAS)
- Phase
- Single phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Rated heat power
- 235.72 KW - 202715 Kcal/h - 810861 BTU/h
- Output heat power
- 216.86 KW - 186498 Kcal/h - 745992 BTU/h
- Heat efficiency (%)
- 92
- Air flow (m³/h)
- 17000
- Available static press
- 200 Pa - 20 mm H₂O
- Termperature rise at 20°C (°C)
- 55
- Effective heat range (m)
- 60
- Oil consumption (Kg/h)
- 18.65
- Natural Gas consumption (m³/h)
- 22.095
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 8.819 - 17.17
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 2550
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 30
- Ø outlet hose - L.max 2 ways (mm - m)
- 600 - 15
- Ø outlet hose - L.max 4 ways (mm - m)
- 400 - 15
- Ø outlet snorkel - L.max (mm - m)
- 100 - 5
- Ø inlet hose - L.max (mm - m)
- 720 - 6
- Length (mm)
- 2245
- Width (mm)
- 982
- Height (mm)
- 1584
- Dry weight (Kg)
- 351
BM2 FORCED AIR SPACE HEATERS JUMBO 235M (OIL-GAS)
BM2 HOT AIR GENERATOR TITAN 185T (OIL-GAS)
- Phase
- Three phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Rated heat power
- 185.54 KW - 159563 Kcal/h - 638254 BTU/h
- Output heat power
- 178.12 KW - 153181 Kcal/h - 612724 BTU/h
- Heat efficiency (%)
- 96
- Air flow (m³/h)
- 16000
- Available static press
- 500 Pa - 50 mm H₂O
- Termperature rise at 20°C (°C)
- 46
- Effective heat range (m)
- 63
- Oil consumption (Kg/h)
- 14.68
- Natural Gas consumption (m³/h)
- 17.682
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 6.981 - 13.63
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 4200
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 50
- Ø outlet hose - L.max 2 ways (mm - m)
- 500 - 30
- Ø outlet hose - L.max 4 ways (mm - m)
- 350 - 25
- Ø outlet snorkel - L.max (mm - m)
- 100 - 6
- Ø inlet hose - L.max (mm - m)
- 720 - 10
- Length (mm)
- 2413
- Width (mm)
- 920
- Height (mm)
- 1620
- Dry weight (Kg)
- 430
BM2 HOT AIR GENERATOR TITAN 185T (OIL-GAS)
FANTASTIC AIR-WATER HEAT PUMP EVI DC R32 THREE-PHASE 35KW INVERTER
- Phase
- Three phase
- Frequency (Hz)
- 50
- Voltage (V)
- 380
- Operating temperature (°C)
- -15~43
- Refrigerating yield
- 25 KW
- Heating power
- 35 KW
- Acoustic pressure
- 55 dB(A)
- Length (mm)
- 1380
- Width (mm)
- 515
- Height (mm)
- 1585
- Dry weight (Kg)
- 190
- Coolant
- R32/R410a
FANTASTIC AIR-WATER HEAT PUMP EVI DC R32 THREE-PHASE 35KW INVERTER
BM2 SP 235 INDIRECT COMBUSTION HEAT AIR GENERATOR 21000 m³/h
- Phase
- Single phase / Three phase
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Max rated heat power
- 202.715 kcal/h - 810.861 BTU/h
- Min rated heat power
- 188.931 kcal/h - 755.722 BTU/h
- Heat efficiency (%)
- 93.4
- Air flow (m³/h)
- 21000
- Termperature rise at 20°C (°C)
- 35
- Length (mm)
- 1450
- Width (mm)
- 911
- Height (mm)
- 2120
- Dry weight (Kg)
- 370
BM2 SP 235 INDIRECT COMBUSTION HEAT AIR GENERATOR 21000 m³/h
BM2 FORCED AIR SPACE HEATERS TITAN 145M (OIL-GAS)
- Phase
- Single phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Rated heat power
- 144.72 KW - 124455 Kcal/h - 497821 BTU/h
- Output heat power
- 138.93 KW - 119477 Kcal/h - 477908 BTU/h
- Heat efficiency (%)
- 96
- Air flow (m³/h)
- 14000
- Available static press
- 300 Pa - 30 mm H₂O
- Termperature rise at 20°C (°C)
- 42
- Effective heat range (m)
- 56
- Oil consumption (Kg/h)
- 11.45
- Natural Gas consumption (m³/h)
- 13.855
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 5.403 - 10.57
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 3100
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 600 - 50
- Ø outlet hose - L.max 2 ways (mm - m)
- 500 - 30
- Ø outlet hose - L.max 4 ways (mm - m)
- 350 - 25
- Ø outlet snorkel - L.max (mm - m)
- 100 - 6
- Ø inlet hose - L.max (mm - m)
- 650 - 10
- Length (mm)
- 2191
- Width (mm)
- 900
- Height (mm)
- 1515
- Dry weight (Kg)
- 361
BM2 FORCED AIR SPACE HEATERS TITAN 145M (OIL-GAS)
BM2 FORCED AIR SPACE HEATERS JUMBO 235T (OIL-GAS)
- Phase
- Three phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 430
- Rated heat power
- 235.72 KW - 202715 Kcal/h - 810861 BTU/h
- Output heat power
- 216.86 KW - 186498 Kcal/h - 745992 BTU/h
- Heat efficiency (%)
- 92
- Air flow (m³/h)
- 17000
- Available static press
- 200 Pa - 20 mm H₂O
- Termperature rise at 20°C (°C)
- 55
- Effective heat range (m)
- 60
- Oil consumption (Kg/h)
- 18.65
- Natural Gas consumption (m³/h)
- 22.095
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 8.819 - 17.17
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 2550
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 30
- Ø outlet hose - L.max 2 ways (mm - m)
- 600 - 15
- Ø outlet hose - L.max 4 ways (mm - m)
- 400 - 15
- Ø outlet snorkel - L.max (mm - m)
- 100 - 5
- Ø inlet hose - L.max (mm - m)
- 720 - 6
- Length (mm)
- 2245
- Width (mm)
- 982
- Height (mm)
- 1584
- Dry weight (Kg)
- 351
BM2 FORCED AIR SPACE HEATERS JUMBO 235T (OIL-GAS)
BM2 FORCED AIR SPACE HEATERS JUMBO 145M (OIL-GAS)
- Phase
- Single phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Rated heat power
- 144.72 KW - 124455 Kcal/h - 497821 BTU/h
- Output heat power
- 134.87 KW - 115992 Kcal/h - 463969 BTU/h
- Heat efficiency (%)
- 93.2
- Air flow (m³/h)
- 12000
- Available static press
- 200 Pa - 20 mm H₂O
- Termperature rise at 20°C (°C)
- 48
- Effective heat range (m)
- 46
- Oil consumption (Kg/h)
- 11.45
- Natural Gas consumption (m³/h)
- 13.664
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 5.436 - 10.53
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 1570
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 600 - 25
- Ø outlet hose - L.max 2 ways (mm - m)
- 500 - 15
- Ø outlet hose - L.max 4 ways (mm - m)
- 350 - 15
- Ø outlet snorkel - L.max (mm - m)
- 100 - 5
- Ø inlet hose - L.max (mm - m)
- 650 - 6
- Length (mm)
- 1905
- Width (mm)
- 890
- Height (mm)
- 1354
- Dry weight (Kg)
- 254
BM2 FORCED AIR SPACE HEATERS JUMBO 145M (OIL-GAS)
BM2 FORCED AIR SPACE HEATERS JUMBO 185M (OIL-GAS)
- Phase
- Single phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Rated heat power
- 185.54 KW - 159563 Kcal/h - 638254 BTU/h
- Output heat power
- 171.07 KW - 147117 Kcal/h - 588470 BTU/h
- Heat efficiency (%)
- 92.2
- Air flow (m³/h)
- 13000
- Available static press
- 200 Pa - 20 mm H₂O
- Termperature rise at 20°C (°C)
- 57
- Effective heat range (m)
- 54
- Oil consumption (Kg/h)
- 14.68
- Natural Gas consumption (m³/h)
- 17.383
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 6.976 - 13.59
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 1550
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 25
- Ø outlet hose - L.max 2 ways (mm - m)
- 500 - 15
- Ø outlet hose - L.max 4 ways (mm - m)
- 350 - 15
- Ø outlet snorkel - L.max (mm - m)
- 100 - 5
- Ø inlet hose - L.max (mm - m)
- 650 - 6
- Length (mm)
- 2013
- Width (mm)
- 912
- Height (mm)
- 1414
- Dry weight (Kg)
- 270
BM2 FORCED AIR SPACE HEATERS JUMBO 185M (OIL-GAS)
BM2 FORCED AIR SPACE HEATERS JUMBO 185T (OIL-GAS)
- Phase
- Three phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 430
- Rated heat power
- 185.54 KW - 159563 Kcal/h - 638254 BTU/h
- Output heat power
- 171.07 KW - 147117 Kcal/h - 588470 BTU/h
- Heat efficiency (%)
- 92.2
- Air flow (m³/h)
- 13000
- Available static press
- 200 Pa - 20 mm H₂O
- Termperature rise at 20°C (°C)
- 57
- Effective heat range (m)
- 54
- Oil consumption (Kg/h)
- 14.68
- Natural Gas consumption (m³/h)
- 17.383
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 6.976 - 13.59
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 1550
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 25
- Ø outlet hose - L.max 2 ways (mm - m)
- 500 - 15
- Ø outlet hose - L.max 4 ways (mm - m)
- 350 - 15
- Ø outlet snorkel - L.max (mm - m)
- 100 - 5
- Ø inlet hose - L.max (mm - m)
- 650 - 6
- Length (mm)
- 2013
- Width (mm)
- 912
- Height (mm)
- 1414
- Dry weight (Kg)
- 270
BM2 FORCED AIR SPACE HEATERS JUMBO 185T (OIL-GAS)
- 1
- 2
- 3
- …
- 6
- chevron_right