Add to wishlist

payment logo

Customer ratings and reviews

Nobody has posted a review yet
in this language
Request offert

BUSINESS AREA

CUMMINS C38 D5 THREE-PHASED DIESEL POWER GENERATOR 35KVA - OPEN

CUMMINS ONAN

C38 D5-A

New product

Phase Type: Single-phase / Three-phase 
Maximum power three-phase LTP: 38 KVA
Maximum power three-phase LTP: 30.4 KW
Continuous power three-phase PRP: 35 KVA
Maximum power three-phase LTP: 28 KVA
Maximum power single-phase LTP: 30 KW
Continuous power single-phase PRP: 30 KVA
Continuous power single-phase PRP: 27 KW

Continuous power PRP: 27 KW
Fuel: Diesel
Frequency: 50 Hz
Voltage: 230 / 400 V
Engine: Cummins
Engine rpm: 1500 rpm
Cooling: Water
Length: 1753 mm
Width: 930 mm
Height: 1238 mm
Dry Weight: 743 Kg

More details

CUMMINS C38 D5 THREE-PHASED DIESEL POWER GENERATOR 35KVA - OPEN View larger

Technical features
Phase Single phase / Three phase
Maximum power single phase (KW) 30
Continuous power single phase (KW) 27
Maximum power single phase (KVA) 30
Continuous power single phase (KVA) 27
Maximum power three phase (KW) 30.4
Continuous power three phase (KW) 28
Maximum power three phase (KVA) 38
Continuous power three phase (KVA) 35
Fuel Diesel
Frequency (Hz) 50
Voltage (V) 230 / 400
Sockets configuration Terminal box
Engine 4 stroke
Engine rpm (rpm) 1500
Speed governor Mechanical
Starting system Electric
Engine capacity (cm³) 2500
Number cylinders 4
Cylinders' position In line
Cooling Liquid
Alternator Synchronous, brushless
Poles 4
Bore x stroke (mm) 91.4x127
Length (mm) 1750
Width (mm) 923
Height (mm) 1240
Dry weight (Kg) 710
Silenced No
Brushes No
Product type Generator
Control unit PowerStart 600
ATS Switch device Optional
Type of alternator Constant Speed
Engine manufacturer Cummins
Precision of voltage regulation ± 2,5%

* The data shown are supplied by the manufacturer, ManelService assumes no responsibility for any incorrect values. Take a look at the attached manufacturer's data sheet.

Details

CUMMINS C38 D5 Control system

Generator set control PowerStart 600

The PowerStart contol is a microprocessor-based generator set monitoring and control system. The control provides a simple operator interface to the generator set, auto/ manual and remote start/stop control and shutdown fault indication. The integration of all control functions into a single control provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet the harsh environment in which gensets are typically applied.

• The PowerStart generator set control is suitable for use on a wide range of generator sets in nonparalleling applications. It is suitable for use with reconnectable or non-reconnectable generators, can be configured for either 50 Hz or 60 Hz and voltage and power connection from 190-600 VAC line-to-line.

• This control includes an intuitive operator interface that allows for complete genset control as well as system metering, fault annunciation, maintenance alarm, over imbalance current, configuration and diagnostics. The interface includes seven generator set status LED lamps with both internationally accepted symbols and English text to comply with customer needs. The interface also includes an LED backlit LCD display with tactile-feel softswitches for easy operation and screen navigation. The manual/auto/stop switch function is integrated into the interface panel.

• All data on the control can be viewed by scrolling through screens with the navigation keys. The control displays the current active fault and a timeordered history of the five previous faults.

• Power for this control is derived from the generator set starting batteries and functions over a voltage range from 8VDC to 16 VDC.

  • Reviews (0)
  • Be the first to write your review !

    RELATED ACCESSORIES


    spedizioni eng
    pagamenti sicuri eng
    esperienza eng
    certificazioni eng
    Phase Single phase / Three phase
    Maximum power single phase (KW) 30
    Continuous power single phase (KW) 27
    Maximum power single phase (KVA) 30
    Continuous power single phase (KVA) 27
    Maximum power three phase (KW) 30.4
    Continuous power three phase (KW) 28
    Maximum power three phase (KVA) 38
    Continuous power three phase (KVA) 35
    Fuel Diesel
    Frequency (Hz) 50
    Voltage (V) 230 / 400
    Sockets configuration Terminal box
    Engine 4 stroke
    Engine rpm (rpm) 1500
    Speed governor Mechanical
    Starting system Electric
    Engine capacity (cm³) 2500
    Number cylinders 4
    Cylinders' position In line
    Cooling Liquid
    Alternator Synchronous, brushless
    Poles 4
    Bore x stroke (mm) 91.4x127
    Length (mm) 1750
    Width (mm) 923
    Height (mm) 1240
    Dry weight (Kg) 710
    Silenced No
    Brushes No
    Product type Generator
    Control unit PowerStart 600
    ATS Switch device Optional
    Type of alternator Constant Speed
    Engine manufacturer Cummins
    Precision of voltage regulation ± 2,5%

    CUMMINS C38 D5 Control system

    Generator set control PowerStart 600

    The PowerStart contol is a microprocessor-based generator set monitoring and control system. The control provides a simple operator interface to the generator set, auto/ manual and remote start/stop control and shutdown fault indication. The integration of all control functions into a single control provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet the harsh environment in which gensets are typically applied.

    • The PowerStart generator set control is suitable for use on a wide range of generator sets in nonparalleling applications. It is suitable for use with reconnectable or non-reconnectable generators, can be configured for either 50 Hz or 60 Hz and voltage and power connection from 190-600 VAC line-to-line.

    • This control includes an intuitive operator interface that allows for complete genset control as well as system metering, fault annunciation, maintenance alarm, over imbalance current, configuration and diagnostics. The interface includes seven generator set status LED lamps with both internationally accepted symbols and English text to comply with customer needs. The interface also includes an LED backlit LCD display with tactile-feel softswitches for easy operation and screen navigation. The manual/auto/stop switch function is integrated into the interface panel.

    • All data on the control can be viewed by scrolling through screens with the navigation keys. The control displays the current active fault and a timeordered history of the five previous faults.

    • Power for this control is derived from the generator set starting batteries and functions over a voltage range from 8VDC to 16 VDC.

    Be the first to write your review !