AXO AIG 2002SM Single Phase Petrol Inverter Generator 2.2 kVA 1.76 kW
Single phase Maximum power (kVA): 2.2
Single phase Maximum power (kW): 1.76
Single phase Continuous power (kVA): 2
Single phase Continuous power (kW): 1.6
Fuel: Petrol
Voltage (Volts): 230 V
Rate (Hz): 50
DC Output (V/A): 12 / 8.3
Fuel carrying capacity (Lt): 4.5
Autonomy (h): from 4 to 10
Noise (dB (A) at 7m): 59
Length (mm): 545
Width (mm): 290
Height (mm): 500
Dry weight (Kg): 27
Engine: Axo
Engine model: X4152F
Cilindrata (cc): 125
Power (Hp) at 3600 rpm: 4.6
Rpm speed (rpm): 4500
Engine starting: Manual
Cooling: Air
Voltage Regulation: Inverter
Protection degree: IP23
Oil Alert: Yes
Economizer: Yes
ATS control unit: No
Battery: No
- Phase
- Single phase
- Maximum power single phase (KW)
- 1.76
- Continuous power single phase (KW)
- 1.6
- Maximum power single phase (KVA)
- 2.2
- Continuous power single phase (KVA)
- 2
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 2 x 220V 16A SCHUKO
- Engine
- X4152F, OHV
- Engine rpm (rpm)
- 4500
- Starting system
- Manual
- Engine capacity (cm³)
- 125
- Cooling
- Air
- Fuel tank capacity (L)
- 4.5
- Consumption (L/h)
- 1.12~0.45
- Running time (h)
- 4 - 10
- Acoustic pressure
- 59 dB(A) at 7 m
- Length (mm)
- 545
- Width (mm)
- 290
- Height (mm)
- 500
- Dry weight (Kg)
- 27
- Silenced
- Yes
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- Inverter
- Engine manufacturer
- Axo
The petrol Axo AIG 2002SM inverter unit is equipped with a multi-phase alternator+ inverter board with stabilised
220V single-phase output.
The THD (total harmonic distortion) value is less than 2%, the voltage accuracy is
between +1% and -1%.
The overload capacity for starting is insignificant.
Connection
220 V: N.2 SCHUKO sockets 16A
12 V DC: N.2 screw type banana plugs one red (+) and one black (-)
Reading instrument
Multifunction digital instrument
Protections
10A fast fuse on the 12V DC
Recommended use
Sophisticated electronic equipment, computers, appliances that are microprocessor-controlled, electronic
boards, electronic scales and likewise.
Safe use
Before use, check the electrical requirements of the user and the simultaneous start-up of the loads to
connect to a compliant socket board.
The pictures are for illustrative purposes only.
KIT MESSA A TERRA 10 METRI
KIT MESSA A TERRA 25 METRI
KIT MESSA A TERRA 35 METRI
- Phase
- Single phase
- Maximum power single phase (KW)
- 1.76
- Continuous power single phase (KW)
- 1.6
- Maximum power single phase (KVA)
- 2.2
- Continuous power single phase (KVA)
- 2
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 2 x 220V 16A SCHUKO
- Engine
- X4152F, OHV
- Engine rpm (rpm)
- 4500
- Starting system
- Manual
- Engine capacity (cm³)
- 125
- Cooling
- Air
- Fuel tank capacity (L)
- 4.5
- Consumption (L/h)
- 1.12~0.45
- Running time (h)
- 4 - 10
- Acoustic pressure
- 59 dB(A) at 7 m
- Length (mm)
- 545
- Width (mm)
- 290
- Height (mm)
- 500
- Dry weight (Kg)
- 27
- Silenced
- Yes
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- Inverter
- Engine manufacturer
- Axo