AXO ACDE 6000M Diesel Generator 6 KVA 4.8 KW
Maximum power (kVA): 6
Single phase Maximum power (kW): 4.8
Single phase Continuous power (kVA): 5.5
Single phase Continuous power (kW): 4.4
Fuel: Diesel
Voltage (Volts): 230
Rate (Hz): 50
DC Output (V/A): 12 / 8.3
Fuel carrying capacity (Lt): 5.5
Autonomy (h): 3.2
Noise (dB (A) at 7m): 78
Battery: Si
Wheels Kit: Optional
Length (mm): 880
Width (mm): 600
Height (mm): 840
Dry weight (Kg): 91
Engine model: Axo AMDE 186
Cilindrata (cc): 406
Power (Hp) at 3600 rpm: 10
Rpm speed (rpm): 3000
Engine starting: Electric 12 Vcc / Manual
Cooling: Air
Voltage Regulation: Capacitor
Protection degree: IP23
Air temperature switch: Yes
Voltmeter: Yes
ATS control unit: No
- Phase
- Single phase
- Maximum power single phase (KW)
- 4.8
- Continuous power single phase (KW)
- 4.4
- Maximum power single phase (KVA)
- 6
- Continuous power single phase (KVA)
- 5.5
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 1 x 220V 16A 2P+T CE - 1 x 220V 32A 2P+T CE
- Engine
- AMDE 186
- Engine rpm (rpm)
- 3000
- Starting system
- Electric 12 Vcc / Manual
- Engine capacity (cm³)
- 406
- Cooling
- Air
- Fuel tank capacity (L)
- 5.5
- Consumption (L/h)
- 1.72
- Running time (h)
- 3.2
- Acoustic pressure
- 78 dB(A) at 7 m
- Length (mm)
- 880
- Width (mm)
- 600
- Height (mm)
- 840
- Dry weight (Kg)
- 91
- Silenced
- No
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- Capacitor
- Engine manufacturer
- Axo
Axo ACDE 6000M is a single phase diesel generator for worksites, designed
and manufactured in Italy. The THD (total harmonic distortion) value is less than 6% and the voltage accuracy
is between +5% and -10%.
The starting capability is greater than 3 times the rated current.
Connection
220 V: N.1 CE socket 16 A 2P+T
N.1 CE socket 32 A 2P+T for full engine power
12 V.cc: N.2 banana plugs, a red one (+) and a black one (-)
Protections
220 V: 15 A and 25 A instant thermal protections (optional: two pole thermal-magnetic circuit breaker)
12 V.cc: 10A fast acting fuse
Reading system
Electronic LED voltmeter for voltage reading.
Recommended use
Powerful electrical equipment, appliances, floodlights and lighting even if sensitive to voltage variations
between no-load and full load.
Added value
The unit will not be damaged by an overload because the engine rpm lowers and the voltage drops to values
under the operating limit, thereby preserving the unit and user. Once the load has been verified as excessive,
it needs to be reduced, without stressing the user in overload.
The images are purely for information.
KIT MESSA A TERRA 10 METRI
KIT MESSA A TERRA 25 METRI
KIT MESSA A TERRA 35 METRI
- Phase
- Single phase
- Maximum power single phase (KW)
- 4.8
- Continuous power single phase (KW)
- 4.4
- Maximum power single phase (KVA)
- 6
- Continuous power single phase (KVA)
- 5.5
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 1 x 220V 16A 2P+T CE - 1 x 220V 32A 2P+T CE
- Engine
- AMDE 186
- Engine rpm (rpm)
- 3000
- Starting system
- Electric 12 Vcc / Manual
- Engine capacity (cm³)
- 406
- Cooling
- Air
- Fuel tank capacity (L)
- 5.5
- Consumption (L/h)
- 1.72
- Running time (h)
- 3.2
- Acoustic pressure
- 78 dB(A) at 7 m
- Length (mm)
- 880
- Width (mm)
- 600
- Height (mm)
- 840
- Dry weight (Kg)
- 91
- Silenced
- No
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- Capacitor
- Engine manufacturer
- Axo