RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries
      RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries

      RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries

      Phase type: Single-phase
      Rated power: 30000 VA
      Voltage: 380/400/415 Vac single phase + N
      Voltage tolerance: ± 20%
      Frequency tolerance: 40/72 Hz
      Power factor: 0,99
      BY PASS
      Rated voltage: 380/400/415 Vac three-phase + N
      Voltage tolerance: ± 15% (selectable from ± 5% to ± 25%)
      Nominal frequency: 50/60 Hz
      Frequency tolerance: ± 5% (selectable from ± 0.25% to ± 10%)
      Number of phases: 3 + N
      OUTPUT and INVERTER OUTPUT
      Rated power: 30000 VA
      Active power: 27000 W
      Output current: 43 A
      Number of phases: 3 + N
      Crest factor (Ipicco/Irms): 3 : 1
      Waveform: Sinusoidal
      Static stability: ± 1%
      Dynamic stability: ± 3% in 10 ms
      Frequency: 50/60 Hz selectable
      Voltage distortion with distorting load: 3%.
      Voltage distortion with linear load: 1%.
      Overload 125% 150% 168% of the rated current for 10' / 1' / 5".
      BATTERIES
      Type: Maintenance-free hermetic lead
      Recharge time: 6 h
      OTHER FEATURES
      Colour: Dark grey RAL 7016
      ESD and bypass remote controls
      Communication: 2 RS232 + 2 SNMP interface slot + dry contact card slot
      Safety Compliance: EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
      Compliance: EMC EN 62040-2 and Directive 2014/30/EU
      Degree of protection: IP20
      AC/AC efficiency: >94%.
      Line-Interactive/Smart Active performance: >98%.
      Noise level (at 1 m): <40 dBA at 1 m - Smart Active Mode
      Remote signals Voltage-free contacts
      Operating temperature: 0 ÷ 40 °C
      Relative humidity: 95% non-condensing

      Weight 335 Kg.
      Length: 850 mm
      width: 440 mm
      Height: 1320 mm

      Custom Quote
      Product: RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries

      PERSONAL DATA


      Ask a question
      Product: RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries
      Offer on letterhead
      Product: RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries
      RIEDMSTK30AT100

      Data sheet

      Phase
      Single phase
      Frequency (Hz)
      50 / 60
      Voltage (V)
      380/400/415 Vac 1PH + N
      Protection degree
      IP20
      Power (VA)
      30000
      Battery type
      maintenance-free hermetic lead
      Operating temperature (°C)
      0 °C / +40 °C
      Acoustic pressure
      48 dB(A) 1 mt
      Length (mm)
      850
      Width (mm)
      440
      Height (mm)
      1320
      Dry weight (Kg)
      335
      Product type
      UPS
      Colour
      Grey

      Specific References

      New

      RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries

      The Multi Sentry series is ideal for the protection of data centers and telecommunication systems, computer networks and critical systems in general, where the risks associated with poor power quality can compromise the continuity of business and services.
      The Multi Sentry series is available in models 10-15-20- 30-40-60-80-100-125-160-200 kVA with three-phase input and output and On Line double conversion technology according to VFI-SS-111 classification (as defined by IEC EN 62040-3).
      Multi Sentry is designed and manufactured with state of the art technology and components,
      and is equipped with an IGBT rectifier for minimum impact on the power line.
      It is also controlled by a DSP (Digital Signal Processor) microprocessor to provide the
      maximum protection against powered loads without impact on downstream systems and to optimize energy savings.

      Zero impact source
      Thanks to the technology used, Multi Sentry solves any problem of insertion in systems where the power supply network has a limited installed power, where the UPS is
      also powered by a generator set or in any case where there are problems of
      compatibility with loads that generate current harmonics; in fact Multi Sentry
      has zero impact on the power source, be it the mains or a generator set:
      - input current distortion of less than 3%.
      - input power factor 0.99
      - power walk-in function that guarantees a progressive rectifier start-up
      - power on delay function, to restart the rectifier starts at
      mains return, if there are several UPS in the system.
      Multi Sentry also plays a filtering and power factor correction role towards the power supply network upstream of the UPS, as it eliminates the harmonic components and reactive power generated by the powered consumers.

      High efficiency
      The use of modern three-level NPC inverters in the entire power range (30÷200)
      allows for an operational efficiency of 96.5%. These technological solutions
      They save more than 50% of the energy dissipated in a year, compared to a similar product on the market with 92% efficiency.
      The exceptional return value makes it possible to recover the initial investment in less than 3 years of operation.

      Battery care system
      Battery management is of paramount importance to ensure operation
      of the uninterruptible power supply in emergency conditions.
      Battery Care System consists of a series of functions and performances that allow to manage the batteries of accumulators in order to obtain the best performances and to extend their working life.

      Battery charging: Multi Sentry is suitable to work with lead-acid batteries.
      hermetic (VRLA), AGM and GEL, open pot and Nickel Cadmium.
      Depending on the type of battery, different charging methods are available:
      - One-level charging, typically used for larger VRLA AGM batteries
      diffusion
      - Recharge at two voltage levels according to the IU characteristic
      - Charge lock system to reduce electrolyte consumption and further extend the life of VRLA batteries.

      Temperature-dependent charging voltage compensation to avoid
      overcharging and overheating of the batteries.
      Battery testing to diagnose performance degradation or failure in time
      on the batteries.

      Protection against deep discharges: in the presence of long lasting and low discharges
      the end-of-discharge voltage is increased, as prescribed by the battery manufacturers, to avoid damage or reduction in battery performance.

      Current ripple: the ripple (residual alternating current component) of charging current is a
      of the most important causes that reduce the reliability and life of the battery.
      Multi Sentry, thanks to the high-frequency charger reduces this value to levels
      negligible, extending its life and maintaining its high performance for a long time.
      Wide voltage range: the rectifier is designed to work with a wide range of voltages.
      range of input voltage values (up to - 40% with half load), reducing the
      the need to discharge the batteries and, consequently, to lengthen them.
      life.

      Images and technical data are not binding.

      RIELLO NetMan 204 PLUSRIELLO NetMan 204 PLUS
          159.00 €Price
          Battery Box BBX 1900 480V BB V6 3T
            • On sale!
            3,045.00 €Price

            4 other products in the same category:

            RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries

            RIELLO MST 30 MULTY SENTRY UPS 30000 VA Without Batteries

            List price
            8,452.16 € tax incl.
            6,928.00 € tax excl.
            Discounted Price
            8,452.16 € tax incl.
            6,928.00 € tax excl.