GENMAC DUPLEX G15YO Generating set 15 KVA 13 KW Open Automatic
Power supply: Diesel
Continuous power PRP (kVA): 13
Continuous power PRP (kW): 11
Stand-by power LTP (kVA) 15
Stand-by power LTP (kW) 12
Power factor cos fi?: 0.8
Phase type: Three-phase
VAC voltage: 400/230 V
Frequency (Hz): 50
Ampere PRP/LTP: 19 / 21 A
Voltage Regulator: AVR
Automatic Control Unit DSE4520
Revolutions per minute RPM: 1500
Length (mm): 1400
Width (mm) 660
Height (mm) 1360
Net weight (kg): 390
- Phase
- Three phase
- Maximum power three phase (KW)
- 12
- Continuous power three phase (KW)
- 11
- Maximum power three phase (KVA)
- 15
- Continuous power three phase (KVA)
- 13
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Engine
- 3TNV88-GMG
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric
- Engine capacity (cm³)
- 1640
- Number cylinders
- 3
- Oil capacity (L)
- 6.7
- Cooling
- Coolant Liquid
- Poles
- 4
- Tank capacity (L)
- 100
- Current (A)
- 21
- Consumption (L/h)
- 2.7 at 75% of the load
- Running time (h)
- 37
- Length (mm)
- 1400
- Width (mm)
- 660
- Height (mm)
- 1360
- Dry weight (Kg)
- 390
- ATS Switch device
- Optional ATS
- Voltage regulator
- AVR
- Engine manufacturer
- Yanmar
Open generator with the following structural characteristics:
Frame:
- Made of high quality steel UNI S235 JR with welded base
- Highly resistant vibration dampers between engine, alternator and crankcase
- Tank with drain for emptying
- Dedicated cable entry area for load connection
- Fuel loading niche
- Feet and four lifting rings fixed to the base
Framework:
- Metal square, with rear closing case
- Dedicated cable entry area for load connection
All machines and components are tested in prototyping, construction and production. A special control procedure during the various stages of production ensures long life and reliability.
QFIA-4520
Protective flap
Thermal-magnetic circuit breaker
Automatic Control Unit DSE4520
- Voltmeter, Frequency Meter, Ammeter
- Reading Generator power (kW, kV Ar, kV A & pf)
- Hour counter
- Fuel tool
- Overload protection (kW & kV Ar)
- Low oil pressure protection
- High refrigerant temperature protection
- Low fuel level protection
- Alternator battery charger failure
- Overrunning protections
Emergency Stop button
Terminal block for connection Automatic Framework
Battery Charger
On/off switch
Non-binding images and technical information.
* Images and technical data are not binding. Please always consult the technical data sheet released by the manufacturer. Manel Service does not assume responsibility for any changes made by the manufacturer.