GREEN POWER GP 12000 ST/KG-A
DISCONTINUED PRODUCT
Maximum three-phase power: 11 KVA NG / 12.1 KVA LPG
Maximum power Three-phase: 9.8 KW NG / 9.7 KW LPG
Fuel: Natural gas/LPG
Voltage: 230/400 V
Motor: KOHLER CH740
Starter: Automatic
Length: 940 mm
Width: 650 mm
Height: 900 mm
Weight: 255 Kg
AVRre
- Phase
- Three phase
- Maximum power three phase (KW)
- 9.8 NG / 9.7 GPL
- Continuous power three phase (KW)
- 8 NG / 8.8 GPL
- Maximum power three phase (KVA)
- 11 NG / 12.1 GPL
- Continuous power three phase (KVA)
- 10 NG / 11 GPL
- Fuel
- LPG / Natural Gas
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Engine
- KOHLER CH740
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Automatico
- Engine capacity (cm³)
- 725
- Number cylinders
- 2
- Cooling
- Air
- Alternator
- MECC ALTE ET20FS-160A
- Poles
- 4
- Consumption (L/h)
- 3,3 m3/h NG / 5.2 L/h GPL
- Acoustic pressure
- 68 dB(A) at 7 m
- Length (mm)
- 940
- Width (mm)
- 650
- Height (mm)
- 900
- Dry weight (Kg)
- 255
- Inverter
- No
- AVR
- Yes
- Compound
- No
- Silenced
- Yes
- Super silenced
- Yes
GREEN POWER GP 12000 ST/KG-A
Model: supersilenced 68dB(A)±3 at 7mt
RAL7035 Engine/alternator monoblock unit coupled through monosupport couplings, installed on a welded steel baseframe,complete with antivibration mountings. Soundproof canopy that can be opened in two section, made of 20/10 sheet steel, soundproof material, internal silencer, handles and stay.
Electronic control unit and a programmable microprocessor, LCD display with backlight OFF/AUTO/TEST/MAN controls, Display of all parameters of the engine and alternator. Diagnostic information of the gen set, Automatic and manual control of the contactors, Mains voltage (on 3 phases), gen set voltage (on 3 phases), 3 gen set current, mains and gen set frequency, RPM counter, Vdc Battery, D+Voltage, kVA. 84 alarm messages available. Alarm history, Overvoltage / under voltage shutdown, overfrequency shutdown, overload shutdown. Serial interface RS 232 for PC.
Technical data for GREEN POWER GP 12000 ST/KG-A
Maximum three-phase power: 11 KVA NG / 12.1 KVA LPG
Maximum power Three-phase: 9.8 KW NG / 9.7 KW LPG
Fuel: Natural gas/LPG
Voltage: 230/400 V
Motor: KOHLER CH740
Starter: Automatic
Length: 940 mm
Width: 650 mm
Height: 900 mm
Weight: 255 Kg
AVRre
* Images and technical data are not binding. Please always consult the technical data sheet released by the manufacturer. Manel Service does not assume responsibility for any changes made by the manufacturer.
Complete your order with: