VINCO Generator set Three-Phase 100 kW/125 kVA Stage II
Rated three-phase power: 100 kW / 125 kVA?
Maximum three-phase power: 110 kW / 138 kVA?
Single-phase power: 100 kW / 125 kW?
Voltage: 230/400 V - 50 Hz?
Amperage: 180 A?
Noise level: 75 dBA measured at 7 m?
Protection rating: IP23?
Maximum altitude: 1000 m a.s.l.?
Brand and model: YTO LR4M3L-D88?
Number of cylinders: 4?
Displacement: 4750 cc?
Engine speed: 1500 min?¹?
Lubrication system: 14 L?
Cooling system: Liquid, capacity 16 L?
Emissions: STAGE II?
Fuel type: Diesel?
Tank capacity: 165 L?
Consumption (100/75/50% load): 26.1 / 19.6 / 13.0 L/h?
Alternator and Control
Alternator model: LK274ES?
Type: Brushless, self-excitation?
Control module: DeepSea DSE6120?
Main functions: Low oil pressure, high engine temperature, excessive speed, emergency stop, fault signaling?
Predisposition: ATS
Dimensions: 277 x 108 x 140 cm?
Weight: 1710 kg
Insulation Cases: H
Injection: Direct
- Phase
- Three phase
- Maximum power three phase (KW)
- 110
- Maximum power three phase (KVA)
- 5.5
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230/400
- Engine
- YTO LR4M3L-D88?
- Emissions Regulations
- Stage 2
- Engine rpm (rpm)
- 1500
- Number cylinders
- 4
- Inyección
- Direct
- Alternator
- LK274ES?
- Single-phase power (KW)
- 100 kW / 125 kW?
- Protection degree
- IP23
- Tank capacity (L)
- 165
- Consumption (L/h)
- 100/75/50% load: 26.1 / 19.6 / 13.0 L/h?
- Running time (h)
- 50 - 80
- Acoustic pressure
- 75 dBA
- Silenced
- Yes
- ATS Switch device
- No ATS
- displacement
- 4750 cc
- Insulation Class
- H
- Three-phase rated power (KW)
- 100 kW / 125 kVA?
- lubrication system
- 14 L
- Cooling system
- Liquid, capacity 16 L?
- Predisposition
- ATS
VINCO Three-Phase Generator 100 kW/125 kVA Stage II
Discover the silenced three-phase generator VINCO LG100YTO, a powerful solution for professional power supply with a three-phase nominal power of 100 kW / 125 kVA and a maximum of 110 kW / 138 kVA. Ideal for construction sites, events and industrial backup, this 1500 rpm diesel generator guarantees reliability with a YTO LR4M3L-D88 engine, 4 cylinders, 4750 cc, liquid cooling (16 L) and Stage 2 emissions.
Main Technical Specifications
Phase type: Three-phase, with single-phase power 100 kW / 125 kW
Voltage / Frequency: 230/400 V - 50 Hz
Fuel: Diesel, 165 L tank, consumption 26.1 / 19.6 / 13.0 L/h (100/75/50% load), autonomy 50-80 hours
Noise level: 75 dBA at 7 m (silenced), dry weight 1710 kg
Protections: IP23, max altitude 1000 m, lubrication 14 L, ATS predisposition (without integrated ATS switchboard)
Technical Features:
Three-phase rated power: 100 kW / 125 kVA?
Maximum three-phase power: 110 kW / 138 kVA?
Single-phase power: 100 kW / 125 kW?
Voltage: 230/400 V - 50 Hz?
Amperage: 180 A?
Noise level: 75 dBA measured at 7 m?
Protection level: IP23?
Maximum altitude: 1000 m a.s.l.?
Brand and Model: YTO LR4M3L-D88?
Number of cylinders: 4?
Displacement: 4750 cc?
Engine speed: 1500 min?¹?
Lubrication system: 14 L?
Cooling system: Liquid, capacity 16 L?
Emissions: STAGE II?
Fuel type: Diesel?
Tank capacity: 165 L?
Consumption (100/75/50% load): 26.1 / 19.6 / 13.0 L/h?
Alternator and Control
Alternator model: LK274ES?
Type: Brushless, self-excitation?
Control module: DeepSea DSE6120?
Main functions: Low oil pressure, high engine temperature, overspeed, emergency stop, fault signaling?
Predisposition: ATS
Dimensions: 277 x 108 x 140 cm?
Weight: 1710 kg
Insulation Cases: H
Initiation: Direct
If you are looking for a generator with different features CLICK HERE.
* Images and technical data are not binding. Please always consult the technical data sheet released by the manufacturer. Manel Service does not assume responsibility for any changes made by the manufacturer.
Complete your order with: