65521

Voltage:230/400 V
Single/three-phase
Three-phase continuous use power: 20 KVA
Nominal power: 5.3/16 Kw
Max MF/TF Power: 5.8/17.5 Kw
Frequency: 50 Hz
Amperage: 29 A
Noise Level: 75 DB (at 7m)
IP Degree of Protection: IP23
Degree of Insulation: H/H
Altitude: <1000m asl
Engine: Fawde
Displacement: 2540 cc
Type of Injection: Direct
No. Cylinders: 4
Engine rpm: 1500/min
Emissions: Stage II
Consumption 100%/75%/50% of load: 3.2/2.4/1.6 l/h
Fuel: Diesel
Tank capacity: 40 L
Cooling System: Coolant
Control unit: DEEPSEA DSE6120
Total capacity of lubrication system: 8 L
Cap. total cooling system 6 L
Alternator Model: Lk184E
Exciter: Brushless - Auto - Excitation
Dimensions L x W x H: 1600 * 740 * 825 mm
Weight: 579 kg
Predisposition: ATS

Download Scheda Tecnica 65521
 
Phase
Single phase / Three phase
Maximum power single phase (KW)
5.8
Continuous power three phase (KW)
20
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Engine
4DW91-29D-YFD10W
Emissions Regulations
Stage 2
Engine rpm (rpm)
1500
Starting system
Elettrico
Engine capacity (cm³)
2540
Number cylinders
4
Cooling
Liquid
Alternator
LK184E
Length (mm)
Width (mm)
740
Height (mm)
825
Engine manufacturer
Fawde
Weight (Kg)
579
Brand

HYUNDAI GENERATOR THREE-PHASE SILENCED 16KW/20KVA STAGEII

Generator Hyundai three-phase silenced StageII power reliability in a single solution

The Hyundai three-phase Silenced StageII Generator is the ideal choice for those looking for

reliable and quiet generator Hyundai StageII to power their home, business or construction site.

With a rated output of 16 kW single-phase and 48 kW three-phase, this generator Hyundai StageII can power a wide range of equipment.

Its main features include:

2540 cc Cummins engine: reliable and compliant with StageII anti-pollution regulations.

Direct injection system: ensures high efficiency and low fuel consumption.

LK184E alternator: robust and reliable, providing a pure sine wave ideal for powering sensitive electronic equipment.

Waterproof" control panel: allows easy and safe monitoring and control of the generator Hyundai StageII.

Emergency safety button: ensures immediate generator Hyundai shutdown in case of need.

Waterproof miniature circuit breaker: protects the generator Hyundai from overloads and short circuits.

Noise level below 75 dB (at 7m): quiet operation that does not disturb neighbours.

IP23 degree of protection: resistant to water and dust.

Large autonomy: 40 litre tank for prolonged operation.

Liquid cooling system: keeps the generator Hyundai at optimum temperatures even under severe working conditions.

Deepsea DSE6120 control unit: provides comprehensive information on Hyundai generator StageII operation.

Provision for ATS: allows automatic Hyundai generator connection in the event of a power failure.

The Hyundai StageII Three-Phase Silenced Generator is the ideal choice for:

Private homes: provides backup in the event of a blackout or to high-power electrical equipment.

Advanced monitoring: Get valuable information on the operation of your generator

with the Deepsea DSE6120 control unit, which provides comprehensive information.

Extended runtime: The large 40-litre fuel tank provides ample fuel capacity for extended operation,

keeping you fuelled for longer.

Built to last: IP23 protects the generator from water and dust, making it suitable for various environments.

Technical characteristics Hyundai Three-Phase Silenced StageII Generator:

Voltage:230/400 V
Single/three-phase
Three-phase continuous use power: 20 KVA
Nominal power: 5.3/16 Kw
Max MF/TF Power: 5.8/17.5 Kw
Frequency: 50 Hz
Amperage: 29 A
Noise Level: 75 DB (at 7m)
IP Degree of Protection: IP23
Degree of Insulation: H/H
Altitude: <1000m asl
Engine: Fawde
Displacement: 2540 cc
Type of Injection: Direct
No. Cylinders: 4
Engine rpm: 1500/min
Emissions: Stage II
Consumption 100%/75%/50% of load: 3.2/2.4/1.6 l/h
Fuel: Diesel
Tank capacity: 40 L
Cooling System: Coolant
Control unit: DEEPSEA DSE6120
Total capacity of lubrication system: 8 L
Cap. total cooling system 6 L
Alternator Model: Lk184E
Exciter: Brushless - Auto - Excitation
Dimensions L x W x H: 1600 * 740 * 825 mm
Weight: 579 kg
Predisposition: ATS

If you are looking for a product similar to Hyundai Three Phase Generator click HERE

The image is purely indicative.

* Images and technical data are not binding. Please always consult the technical data sheet released by the manufacturer. Manel Service does not assume responsibility for any changes made by the manufacturer.

Complete your order with:

16 other products in the same category:

Product added to wishlist
Product added to compare.