GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA
      GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA
      GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA

      GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA

      Phase Type: Single-Phase / Three-Phase
      Single-Phase Continuous Power: 2.6KVA / 2.0KW
      Single-Phase Maximum Power: 2.7KVA / 2.1KW
      Three-Phase Continuous Power: 7.8KVA / 6.2KW
      Three-Phase Maximum Power: 8.1KVA / 6.5KW
      Motor: Kohler KDW1003
      Emissions Standard: Stage V
      Starting: Electric
      Power Supply: Diesel
      Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
      Voltage: 230 / 400 V
      Frequency: 50 Hz
      Motor RPM: 1500 rpm
      Tank Capacity: 50 l
      Autonomy @ 75%: 25 h fixed rpm
      Voltage regulator: AVR
      Sound pressure @7m: 63 dBa
      Length (mm): 1475
      Width (mm): 710
      Height (mm): 1060
      Dry weight (Kg): 411

      List price
      8,363.10 € tax incl.
      6,855.00 € tax excl.
      Discounted Price
      8,363.10 € tax incl.
      6,855.00 € tax excl.
      Shipping from 135.00 € to Italy buy it today.
      Calculate Shipping Cost
      Custom Quote
      Product: GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA

      PERSONAL DATA


      Ask a question
      Product: GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA
      Offer on letterhead
      Product: GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA
      GENMAC
      Urban-Rent G9KS-M5

      Data sheet

      Phase
      Single phase / Three phase
      Maximum power single phase (KW)
      2.7
      Continuous power single phase (KW)
      2.6
      Maximum power single phase (KVA)
      2.1
      Continuous power single phase (KVA)
      2
      Maximum power three phase (KW)
      6.5
      Continuous power three phase (KW)
      6.2
      Maximum power three phase (KVA)
      8.1
      Continuous power three phase (KVA)
      7.8
      Fuel
      Diesel
      Frequency (Hz)
      50
      Voltage (V)
      230 / 400
      Sockets configuration
      1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
      Engine
      Kohler KDW1003
      Emissions Regulations
      Stage 5
      Engine rpm (rpm)
      1500
      Starting system
      Electric
      Cooling
      Water
      Poles
      2
      Fuel tank capacity (L)
      50
      Running time (h)
      25
      Acoustic pressure
      63 dB(A) at 7 m
      Length (mm)
      1475
      Width (mm)
      710
      Height (mm)
      1060
      Dry weight (Kg)
      411
      Silenced
      Yes
      Super silenced
      Yes
      ATS Switch device
      Optional
      Voltage regulator
      AVR
      Engine manufacturer
      Kohler

      Specific References

      New

      GENMAC Urban-Rent G9KS-M5 THREE-PHASE GENERATOR 8,1KVA

      The generator GENMAC Urban-Rent G9KS-M5 three-phase is equipped with a Kohler diesel-powered engine capable of delivering a power of 8,1KVA with AVR voltage regulator.

      The high quality professional silenced diesel generator of the construction series, Genmac Urban-Rent with power of 8,1KVA, produced by Italian company Genmac. The generator is equipped with an oversized engine with water cooling and a practical electric starter.

      The Genmac Urban-Rent silenced generator specific for mobile and rental applications. Easy to use and move. It mounts the latest generation engine with low emissions, for energy that respects the environment.

      For this line of generators is possible the supply of a differential protection circuit, in addition it is possible the supply of trolleys for the handling of the unit.

      Genmac 8,1KVA generators are highly reliable machines, built with quality components to be used in the professional field, where reliability is fundamental.

      Genmac generators are supplied with AVR card, tank with collection tank and central lifting hook as standard on all models.

      Control Panel

      The control panel is composed as follows:
      No. 1 CEE 32A 400V
      No. 1 CEE 16A 400V
      No. 2 CEE 16A 230V
      No. 1 Schuko 16A 230V
      Thermal switch
      Magnetothermal switch
      DSE4510 control panel
      - Generator power reading (kW, kV Ar, kV A & pf)
      - Overload Protection (kW & kV Ar)
      - Low Oil Pressure Protection
      - High Coolant Temperature Protection
      - Low Fuel Level Protection
      - Alternator Battery Charging Failure
      - Overspeed Protections
      - Oil Pressure and Engine Temperature Readout
      Fuel Level Analog Instrument
      Emergency Stop Button
      Remote Start/Auto Panel Connector
      On/Off Switch

      AVR Voltage Regulator

      The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.

      The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.

      TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Urban-Rent G9KS-M5 8,1KVA

      Phase Type: SinglePhase / ThreePhase
      SinglePhase Continuous Power: 2.6KVA / 2.0KW
      SinglePhase Maximum Power: 2.7KVA / 2.1KW
      ThreePhase Continuous Power: 7.8KVA / 6.2KW
      ThreePhase Maximum Power: 8.1KVA / 6.5KW
      Motor: Kohler KDW1003
      Emissions Standard: Stage V
      Starting: Electric
      Power Supply: Diesel
      Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
      Voltage: 230 / 400 V
      Frequency: 50 Hz
      Motor RPM: 1500 rpm
      Tank Capacity: 50 l
      Autonomy @ 75%: 25 h fixed rpm
      Voltage regulator: AVR
      Sound pressure @7m: 63 dBa
      Length (mm): 1475
      Width (mm): 710
      Height (mm): 1060
      Dry weight (Kg): 411

      If you are looking for another product then you can consult other terrestrial generators in our catalog.

      Images and technical data are not binding.

      RADIOCONTROL for models with electric start and control panel Portables and Worx
          SELLABLE IN WITH GENMAC GENERATOR Adjustable earth fault breake Rent
          340.00 €Price
          RADIOCONTROL for models with electric start and control panel Portables and Worx
              FOR GENERATING SETS
              SELLABLE IN WITH GENMAC GENERATOR Battery switch Rent
              110.00 €Price
              RADIOCONTROL for models with electric start and control panel Portables and Worx
                  FOR GENERATING SETS
                  SELLABLE IN WITH GENMAC GENERATOR Water separator Rent
                  230.00 €Price

                  4 other products in the same category:

                  GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced

                  GENMAC Urban-Rent G9KS-M5 GENERATOR 8,1KVA

                  List price
                  8,363.10 € tax incl.
                  6,855.00 € tax excl.
                  Discounted Price
                  8,363.10 € tax incl.
                  6,855.00 € tax excl.