GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA
      GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA

      GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA

      Urban G11600KS-M5

      Phase Type: Single-Phase/Three-Phase
      Single-Phase Continuous Power: 3.5KVA / 2.8KW
      Single-Phase Maximum Power: 4KVA / 3.2KW
      Three-Phase Continuous Power: 10.6KVA / 8.5KW
      Three-Phase Maximum Power: 11.8KVA / 9.4KW
      Motor: Kohler KDW702
      Emissions Standard: Stage V
      Starting: Electric
      Power Supply: Diesel
      Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
      Voltage: 230 / 400 V
      Frequency: 50 Hz
      Motor RPM: 3000 rpm
      Tank Capacity: 50 l
      Autonomy @ 75%: 17 h fixed rpm
      Voltage regulator : AVR
      Sound pressure @7m: 68 dBa
      Length (mm): 1475
      Width (mm): 710
      Height (mm): 1060
      Dry weight (Kg): 400

      Custom Quote
      Product: GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA

      PERSONAL DATA


      Ask a question
      Product: GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA
      Offer on letterhead
      Product: GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA
      GENMAC
      Urban G11600KS-M5

      Data sheet

      Phase
      Single phase / Three phase
      Maximum power single phase (KW)
      3.2
      Continuous power single phase (KW)
      2.8
      Maximum power single phase (KVA)
      4
      Continuous power single phase (KVA)
      3.5
      Maximum power three phase (KW)
      9.4
      Continuous power three phase (KW)
      8.5
      Maximum power three phase (KVA)
      11.8
      Continuous power three phase (KVA)
      10.6
      Fuel
      Diesel
      Frequency (Hz)
      50
      Voltage (V)
      230 / 400
      Sockets configuration
      1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
      Engine
      Kohler KDW702
      Emissions Regulations
      Stage 5
      Engine rpm (rpm)
      3000
      Starting system
      Electric
      Cooling
      Water
      Poles
      2
      Fuel tank capacity (L)
      50
      Running time (h)
      17
      Acoustic pressure
      68 dB(A) at 7 m
      Length (mm)
      1475
      Width (mm)
      710
      Height (mm)
      1060
      Dry weight (Kg)
      400
      Silenced
      Yes
      Super silenced
      Yes
      ATS Switch device
      Optional
      Voltage regulator
      AVR
      Engine manufacturer
      Kohler

      Specific References

      New

      GENMAC URBAN G11600KS-M5 SINGLE-PHASE / THREE-PHASE GENERATOR 11,8KVA

      The generator GENMAC Urban G11600KS-M5 Single-phase / Three-phase is equipped with a Kohler KDW702 Stage V diesel-powered engine capable of  delivering a power of 11,8KVA with AVR voltage regulator.

      The high quality professional silenced diesel generator of the construction series, Genmac Urban with power of 11,8KVA, produced by Italian company Genmac. The generator is equipped with an oversized engine with water cooling and a practical electric starter.

      For this line of generators is possible the supply of a differential protection circuit, in addition is possible the supply of trolleys for the handling of the unit.

      The Stage V engine allows the use of the generator set also for mobile use, for example for road construction sites and rental services. The generator is suitable for applications in different contexts such as: hospitals, industries, shopping centers, hotels, airports, banks, universities, stadiums, offices, etc..

      Genmac 11,8KVA generators are highly reliable machines, built with quality components to be used in professional field, where reliability is fundamental.

      Genmac Urban generators are supplied with AVR card, tank with collection tank and central lifting hook as standard on all models.

      AVR Voltage Regulator

      The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.

      The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.

      TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Urban G11600KS-M5 11,8KVA

      Phase Type: SinglePhase/ThreePhase
      SinglePhase Continuous Power: 3.5KVA / 2.8KW
      SinglePhase Maximum Power: 4KVA / 3.2KW
      ThreePhase Continuous Power: 10.6KVA / 8.5KW
      ThreePhase Maximum Power: 11.8KVA / 9.4KW
      Motor: Kohler KDW702
      Emissions Standard: Stage V
      Starting: Electric
      Power Supply: Diesel
      Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
      Voltage: 230 / 400 V
      Frequency: 50 Hz
      Motor RPM: 3000 rpm
      Tank Capacity: 50 l
      Autonomy @ 75%: 17 h fixed rpm
      Voltage regulator : AVR
      Sound pressure @7m: 68 dBa
      Length (mm): 1475
      Width (mm): 710
      Height (mm): 1060
      Dry weight (Kg): 400

      If you are looking for another product then you can consult other terrestrial generators in our catalog.

      Images and technical data are not binding.

      Integer eget turpis non ipsum tempor pellentesque quis eget erat. Duis ipsum leo, pulvinar nec eros hendrerit, consequat tincidunt augue. Proin et est at velit lobortis varius sed sed lectus. Vivamus vitae neque nibh. Proin et lectus dolor. Donec a velit ipsum. Morbi vel nisi cursus, cursus urna a, ornare ex. Mauris vitae feugiat diam. Praesent scelerisque ex faucibus nisl pulvinar vulputate. Maecenas et molestie neque. Morbi sed metus egestas, pharetra sapien eu, efficitur felis. Phasellus facilisis ex id lorem rhoncus efficitur. Aenean varius nec lacus

      GENMAC TRANSFER SWITCH MTS 4P 16A
          Generator power singlephase: 6 KW Protection degree: IP44 Length: 98 mm Width: 200 mm Height: 254 mm Weight: 2.5 Kg
          135.00 €Price
          GENMAC AUTOMATIC TRANSFER SWITCH ATS-L4520
              Generator power singlephase: 9 KW Protection degree: IP65 Length: 180 mm Width: 350 mm Height: 450 mm Weight: 20 Kg
              612.00 €Price
              GENMAC URBAN SLOW SPEED TRAILER
                  GENMAC SLOW SPEED TRAILER for URBAN generators
                  519.75 €Price
                  RADIOCONTROL for models with electric start and control panel Portables and Worx
                      SELLABLE IN WITH GENMAC GENERATOR Earth fault breaker Urban single phase
                      160.00 €Price
                      GENMAC URBAN SLOW SPEED TRAILER
                          GENMAC FAST SPEED TRAILER for URBAN generators
                          2,046.21 €Price

                          4 other products in the same category:

                          GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced

                          GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA

                          List price
                          13,871.40 € tax incl.
                          11,370.00 € tax excl.
                          Discounted Price
                          7,315.43 € tax incl.
                          5,996.25 € tax excl.