List price

76 280,00 € tax excl.
93 061,60 € tax incl.

93 061,60 € tax incl.

Special price

44 250,00 € tax excl.
53 985,00 € tax incl.

53 985,00 € tax incl.

Estimated costs

bx_loader
400,00 €

Add to wishlist

payment logo

Customer ratings and reviews

Nobody has posted a review yet
in this language
Request offert

BUSINESS AREA

KOHLER 80EFOZDJ Three-phase 100 kVA 50 Hz Marine Generator Set

KOHLER

80EFOZDJ

New product

Phase Type: Three-Phase
Continuous three-phase power: 80 KW
Continuous three-phase power: 100 KVA
Brushless alternator with permanent magnets
Heat exchanger/ Cooled keel
Fuel: Diesel
Frequency: 50 Hz
Voltage: 110/190 V, 110/220 V, 120/208 V, 115/230 V, 220/380 V, 230/400 V, 240/416 V
Engine: John Deere
Electrical system 12v or 24v d.c.
Engine revs: 1500 rpm
Length: 1829 mm
Width: 831 mm
Height: 1032 mm
Dry weight: 1320 Kg

More details

KOHLER 80EFOZDJ Three-phase 100 kVA 50 Hz Marine Generator Set View larger
Technical features
Phase Three phase
Continuous power three phase (KW) 80
Continuous power three phase (KVA) 100
Fuel Diesel
Frequency (Hz) 50
Engine John Deere
Emissions Regulations Tier III
Engine rpm (rpm) 1500
Speed governor Electronic
Engine capacity (cm³) 4480
Number cylinders 4
Cylinders' position In line
Cooling Water
Inyección Direct
Alternator Permanent magnets
Poles 4
Bore x stroke (mm) 106 x 127
Compression ratio 16.7:1
Motor insulation class H
Consumption (L/h) 18.54 @ 75%
Length (mm) 1830
Width (mm) 830
Height (mm) 1032
Dry weight (Kg) 1032
Silenced Yes
Super silenced Yes
Brushes No
PMG Yes
Input voltage (V) 12 or 24
Type of combustion Direct
Product type Generator
Type of alternator Constant Speed
Voltage regulator AVR
Engine manufacturer John Deere

* The data shown are supplied by the manufacturer, ManelService assumes no responsibility for any incorrect values. Take a look at the attached manufacturer's data sheet.

Details

KOHLER 80EFOZDJ Three-phase 100 kVA 50 Hz Marine Generator Set

KOHLER 80EFOZDJ three-phase 100 KVA marine generator with 1500 rpm motor and parallel switchboard. The KOHLER 80EFOZDJ marine generator is built with an aluminium soundproofing casing that makes it super-silent. The KOHLER 80EFOZDJ marine generator is built with a John Deere 4 cylinder diesel engine. The KOHLER 80EFOZDJ marine generator alternator is brushless with AVR voltage regulator and water-cooled. Suitable for parallel mounting on large boats.


Engine Features
- One-side serviceability of fuel system, lubrication system, and air cleaner
- Low oil pressure cutout
- High water temperature cutout
- Loss of coolant cutout
- Overcrank cutout
- Belt guard
- Optional digital gauge
- Disposable oil filter
- Extended oil drain
- PTO options: 12- or 24-volt electric clutch


Controller Features
- A graphical display and pushbutton/rotary selector dial provide easy, local data access.
- Measurements are selectable in metric or English units.
- The controller supports Modbusr protocol with serial bus (RS-485) or Ethernet networks.
- Scrolling display shows critical data at a glance.
- Graphical display of power metering (kW, kVA, V, I, PF, and VAR).
- Integrated hybrid voltage regulator providing 0.5% regulation.
- Built-in alternator thermal overload protection.

Decision-Maker 3500 Paralleling Controller

Provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility. The Decision-Maker 3500 controller uses a patented hybrid voltage regulator and unique software logic to manage alternator thermal overload protection features normally
requiring additional hardware. Additional features include:
- AC Output Voltage Regulator Adjustment. The voltage adjustment provides a maximum adjustment of ±10% of the system voltage.
- Alarm Silence. The controller can be set up to silence the alarm horn only when in the AUTO mode for NFPA-110 application or Always for user convenience.
- Alternator Protection. The controller provides generator set overload and short circuit protection matched to each alternator for the particular voltage/phase configuration.
- Automatic Restart. The controller automatic restart feature initiates the start routine and recrank after a failed start attempt.
- Cyclic Cranking. The controller has programmable cyclic cranking.
- ECM Diagnostics. The controller displays engine ECM fault code descriptions to help in engine troubleshooting.
- Engine Start Aid. The configurable starting aid feature provides customized control for an optional engine starting aid.
- Event Logging. The controller keeps a record (up to 1000 entries) for warning and shutdown faults. This fault information becomes a stored record of system events and can be reset.
- Historical Data Logging. Total number of successful starts of the generator is recorded and displayed.
- Integrated Hybrid Voltage Regulator. The voltage regulator provides ±0.5% no-load to full-load RMS voltage regulation with three-phase sensing.
- Lamp Test. Press the alarm silence/lamp test button to verify functionality of the indicator lights.
- LCD Display. Adjustable contrast for improving visibility.
- Measurement Units. The controller provides selection of English or metric displays.
- Power Metering. Controller graphical display provides voltage, current, power factor, kW, kVA, and kVAR.
- Programming Access (USB). Provides software upgrades and diagnostics with PC software tools.
- Remote Reset. The remote reset function supports acknowledging and resetting faults and allows restarting of the generator set without going to the master control switch off/reset position.
- Run Time Hourmeter. The generator set run time is displayed.
- Time Delay Engine Cooldown (TDEC). The TDEC provides a time delay before the generator set shuts down.
- Time Delay Engine Start (TDES). The TDES provides a time delay before the generator set starts.
- Voltage Selection Menu. This menu provides the capability to switch the generator output voltage. NOTE: Generator set output leads may require reconnection.

- Paralleling Functions:
- Bus sensing
- First on logic
- Synchronizing
- Communication based isochronous load sharing
- Droop load sharing
- External controlled load sharing via analog bias signals

Non-binding images and technical data.

  • Reviews (0)
  • Be the first to write your review !

    spedizioni eng
    pagamenti sicuri eng
    esperienza eng
    certificazioni eng
    Phase Three phase
    Continuous power three phase (KW) 80
    Continuous power three phase (KVA) 100
    Fuel Diesel
    Frequency (Hz) 50
    Engine John Deere
    Emissions Regulations Tier III
    Engine rpm (rpm) 1500
    Speed governor Electronic
    Engine capacity (cm³) 4480
    Number cylinders 4
    Cylinders' position In line
    Cooling Water
    Inyección Direct
    Alternator Permanent magnets
    Poles 4
    Bore x stroke (mm) 106 x 127
    Compression ratio 16.7:1
    Motor insulation class H
    Consumption (L/h) 18.54 @ 75%
    Length (mm) 1830
    Width (mm) 830
    Height (mm) 1032
    Dry weight (Kg) 1032
    Silenced Yes
    Super silenced Yes
    Brushes No
    PMG Yes
    Input voltage (V) 12 or 24
    Type of combustion Direct
    Product type Generator
    Type of alternator Constant Speed
    Voltage regulator AVR
    Engine manufacturer John Deere

    KOHLER 80EFOZDJ Three-phase 100 kVA 50 Hz Marine Generator Set

    KOHLER 80EFOZDJ three-phase 100 KVA marine generator with 1500 rpm motor and parallel switchboard. The KOHLER 80EFOZDJ marine generator is built with an aluminium soundproofing casing that makes it super-silent. The KOHLER 80EFOZDJ marine generator is built with a John Deere 4 cylinder diesel engine. The KOHLER 80EFOZDJ marine generator alternator is brushless with AVR voltage regulator and water-cooled. Suitable for parallel mounting on large boats.


    Engine Features
    - One-side serviceability of fuel system, lubrication system, and air cleaner
    - Low oil pressure cutout
    - High water temperature cutout
    - Loss of coolant cutout
    - Overcrank cutout
    - Belt guard
    - Optional digital gauge
    - Disposable oil filter
    - Extended oil drain
    - PTO options: 12- or 24-volt electric clutch


    Controller Features
    - A graphical display and pushbutton/rotary selector dial provide easy, local data access.
    - Measurements are selectable in metric or English units.
    - The controller supports Modbusr protocol with serial bus (RS-485) or Ethernet networks.
    - Scrolling display shows critical data at a glance.
    - Graphical display of power metering (kW, kVA, V, I, PF, and VAR).
    - Integrated hybrid voltage regulator providing 0.5% regulation.
    - Built-in alternator thermal overload protection.

    Decision-Maker 3500 Paralleling Controller

    Provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility. The Decision-Maker 3500 controller uses a patented hybrid voltage regulator and unique software logic to manage alternator thermal overload protection features normally
    requiring additional hardware. Additional features include:
    - AC Output Voltage Regulator Adjustment. The voltage adjustment provides a maximum adjustment of ±10% of the system voltage.
    - Alarm Silence. The controller can be set up to silence the alarm horn only when in the AUTO mode for NFPA-110 application or Always for user convenience.
    - Alternator Protection. The controller provides generator set overload and short circuit protection matched to each alternator for the particular voltage/phase configuration.
    - Automatic Restart. The controller automatic restart feature initiates the start routine and recrank after a failed start attempt.
    - Cyclic Cranking. The controller has programmable cyclic cranking.
    - ECM Diagnostics. The controller displays engine ECM fault code descriptions to help in engine troubleshooting.
    - Engine Start Aid. The configurable starting aid feature provides customized control for an optional engine starting aid.
    - Event Logging. The controller keeps a record (up to 1000 entries) for warning and shutdown faults. This fault information becomes a stored record of system events and can be reset.
    - Historical Data Logging. Total number of successful starts of the generator is recorded and displayed.
    - Integrated Hybrid Voltage Regulator. The voltage regulator provides ±0.5% no-load to full-load RMS voltage regulation with three-phase sensing.
    - Lamp Test. Press the alarm silence/lamp test button to verify functionality of the indicator lights.
    - LCD Display. Adjustable contrast for improving visibility.
    - Measurement Units. The controller provides selection of English or metric displays.
    - Power Metering. Controller graphical display provides voltage, current, power factor, kW, kVA, and kVAR.
    - Programming Access (USB). Provides software upgrades and diagnostics with PC software tools.
    - Remote Reset. The remote reset function supports acknowledging and resetting faults and allows restarting of the generator set without going to the master control switch off/reset position.
    - Run Time Hourmeter. The generator set run time is displayed.
    - Time Delay Engine Cooldown (TDEC). The TDEC provides a time delay before the generator set shuts down.
    - Time Delay Engine Start (TDES). The TDES provides a time delay before the generator set starts.
    - Voltage Selection Menu. This menu provides the capability to switch the generator output voltage. NOTE: Generator set output leads may require reconnection.

    - Paralleling Functions:
    - Bus sensing
    - First on logic
    - Synchronizing
    - Communication based isochronous load sharing
    - Droop load sharing
    - External controlled load sharing via analog bias signals

    Non-binding images and technical data.

    Be the first to write your review !