AXO AEDE 12000TK Three Phase Diesel Generator Avr 14 KVA 11.2 KW
Single phase Maximum power (kVA): 4.6
Single phase Maximum power (kW): 4
Single phase Continuous power (kVA): 3.68
Single phase Continuous power (kW): 3.2
Three phase Maximum power (kVA): 14
Three phase Maximum power (kW): 12
Three phase Continuous power (kVA): 11.2
Three phase Continuous power (kW): 9.6
Fuel: Diesel
Voltage (Volts): 230 V / 400 V
Rate (Hz): 50
DC Output (V/A): 12 / 8.3
Fuel carrying capacity (Lt): 35
Autonomy (h): 12
Noise (dB (A) at 7m): 73
Length (mm): 1000
Width (mm): 670
Height (mm): 880
Dry weight (Kg): 210
Engine: Axo
Engine model: AMDE 2L290
Cilindrata (cc): 954
Power (Hp) at 3600 rpm: 18
Rpm speed (rpm): 3000
Engine starting: Electric
Cooling: Air
Voltage Regulation: Avr
Protection degree: IP23
Oil Alert: Yes
Voltmeter: Yes
ATS control unit: Optional
Battery: Yes
Two pole residual-current device: Yes
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 3.68
- Continuous power single phase (KW)
- 3.2
- Maximum power single phase (KVA)
- 4.6
- Continuous power single phase (KVA)
- 4
- Maximum power three phase (KW)
- 11.2
- Continuous power three phase (KW)
- 9.6
- Maximum power three phase (KVA)
- 14
- Continuous power three phase (KVA)
- 12
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x 380V 16A 3P+N CE - 2 x 220V 16A SCHUKO
- Engine
- AMDE 2L290
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 954
- Cooling
- Air
- Fuel tank capacity (L)
- 35
- Consumption (L/h)
- 2.92
- Running time (h)
- 12
- Acoustic pressure
- 79 dB(A) at 7 m
- Length (mm)
- 900
- Width (mm)
- 570
- Height (mm)
- 800
- Dry weight (Kg)
- 210
- Silenced
- Yes
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Axo
The semi-silent eco Axo AEDE 12000TK generator is equipped with a 4-stroke twin cylinder air cooled diesel
engine (23 Hp). This is a handy portable generator for emergencies and household use.
The differential magneto-thermal switch provides protection against overloads, acting as a safeguard to protect
operators against hazards.
The oil level indicator warns when the oil level is low. It also has an extra large
silencer for even quieter operation.
The AVR regulator is able to provide stable voltage and current.
It has an instrument for digital electric control, analogue for the engine.
● Rated electric power output 12.0 kVA equivalent to 10.0 kW
● In the three-phase configuration you can obtain a third of the single-phase power on each phase
● In the three-phase configuration the single-phase power is further protected by a designated bipolar
magneto-thermal switch
The images are purely for information.
KIT MESSA A TERRA 10 METRI
KIT MESSA A TERRA 25 METRI
KIT MESSA A TERRA 35 METRI
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 3.68
- Continuous power single phase (KW)
- 3.2
- Maximum power single phase (KVA)
- 4.6
- Continuous power single phase (KVA)
- 4
- Maximum power three phase (KW)
- 11.2
- Continuous power three phase (KW)
- 9.6
- Maximum power three phase (KVA)
- 14
- Continuous power three phase (KVA)
- 12
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x 380V 16A 3P+N CE - 2 x 220V 16A SCHUKO
- Engine
- AMDE 2L290
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 954
- Cooling
- Air
- Fuel tank capacity (L)
- 35
- Consumption (L/h)
- 2.92
- Running time (h)
- 12
- Acoustic pressure
- 79 dB(A) at 7 m
- Length (mm)
- 900
- Width (mm)
- 570
- Height (mm)
- 800
- Dry weight (Kg)
- 210
- Silenced
- Yes
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Axo