AXO ACDE 3000M Single Phase Gasoline generator 3 KVA 2.4 KW
Single phase Maximum power (kVA): 3
Single phase Maximum power (kW): 2.4
Single phase Continuous power (kVA): 2.8
Single phase Continuous power (kW): 2.2
Fuel: Gasoline
Voltage (Volts): 230
Rate (Hz): 50
DC Output (V/A): 12 / 8.3
Fuel carrying capacity (Lt): 3.5
Autonomy (h): 3.5
Noise (dB (A) at 7m): 72
Length (mm): 700
Width (mm): 420
Height (mm): 450
Dry weight (Kg): 32
Engine: Axo
Engine model: Amg 210
Cilindrata (cc): 208
Power (Hp) at 3600 rpm: 6.8
Rpm speed (rpm): 3000
Engine starting: Manual
Cooling: Air
Voltage Regulation: Capacitor
Protection degree: IP23
Oil Alert: Yes
Air temperature switch: Yes
Voltmeter: No
ATS control unit: No
- Phase
- Single phase
- Maximum power single phase (KW)
- 2.4
- Continuous power single phase (KW)
- 2.2
- Maximum power single phase (KVA)
- 3
- Continuous power single phase (KVA)
- 2.8
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 2 x 220V 16A SCHUKO
- Engine
- AMG 210
- Engine rpm (rpm)
- 3000
- Starting system
- Manual
- Engine capacity (cm³)
- 208
- Cooling
- Air
- Fuel tank capacity (L)
- 3.5
- Consumption (L/h)
- 1
- Running time (h)
- 3.5
- Acoustic pressure
- 72 dB(A) at 7 m
- Length (mm)
- 700
- Width (mm)
- 420
- Height (mm)
- 450
- Dry weight (Kg)
- 38
- Silenced
- No
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- Capacitor
- Engine manufacturer
- Axo
Axo ACG 3000M current generator is equipped with a single-phase inverter designed and manufactured in Italy.
The THD (total harmonic distortion) value is less than 6%, the voltage accuracy is between +5% and -10%.
The starting capability is 3 times the rated current.
Connection
220 V: 2 SCHUKO 16A outlet
12 V DC: 2 screw type banana plugs one red (+) and one black (-)
Protections
220 V: 10A resettable instantaneous thermal protection
12 V DC: 10A fast fuse
Recommended use
Low power electrical equipment, appliances and lighting insensitive to voltage variations between no load and full load.
Added value
The unit will not be damaged by an overload because the engine rpm lowers and the voltage drops to values
under the operating limit, thereby preserving the unit and user. Once the load has been verified as excessive,
it needs to be reduced, without stressing the user in overload.
The images are purely for information.
KIT MESSA A TERRA 10 METRI
KIT MESSA A TERRA 25 METRI
KIT MESSA A TERRA 35 METRI
- Phase
- Single phase
- Maximum power single phase (KW)
- 2.4
- Continuous power single phase (KW)
- 2.2
- Maximum power single phase (KVA)
- 3
- Continuous power single phase (KVA)
- 2.8
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 2 x 220V 16A SCHUKO
- Engine
- AMG 210
- Engine rpm (rpm)
- 3000
- Starting system
- Manual
- Engine capacity (cm³)
- 208
- Cooling
- Air
- Fuel tank capacity (L)
- 3.5
- Consumption (L/h)
- 1
- Running time (h)
- 3.5
- Acoustic pressure
- 72 dB(A) at 7 m
- Length (mm)
- 700
- Width (mm)
- 420
- Height (mm)
- 450
- Dry weight (Kg)
- 38
- Silenced
- No
- Super silenced
- No
- ATS Switch device
- No
- Voltage regulator
- Capacitor
- Engine manufacturer
- Axo