Add to wishlist

payment logo

Customer ratings and reviews

Nobody has posted a review yet
in this language
Request offert

BUSINESS AREA

CUMMINS C400 D5eB THREE-PHASED DIESEL POWER GENERATOR 364KVA OPEN STAGE 3A

CUMMINS ONAN

C400 D5eB-A

New product

Phase Type: Three-phase 
Maximum power three-phase LTP: 400 KVA
Maximum power three-phase LTP: 320 KW
Continuous power three-phase PRP: 364 KVA
Maximum power three-phase LTP: 291 KVA

Fuel: Diesel
Frequency: 50 Hz
Voltage: 400 V
Engine: Cummins
Engine rpm: 1500 rpm
Cooling: Air
Length: 3376 mm
Width: 1500 mm
Height: 2192 mm
Dry Weight: 3884 Kg

More details

CUMMINS C400 D5eB THREE-PHASED DIESEL POWER GENERATOR 364KVA OPEN STAGE 3AView larger
  • CUMMINS C400 D5eB THREE-PHASED DIESEL POWER GENERATOR 364KVA OPEN STAGE 3A
  • CUMMINS C400 D5eB THREE-PHASED DIESEL POWER GENERATOR 364KVA OPEN STAGE 3A

Technical features
PhaseThree phase
Maximum power three phase (KW)320
Continuous power three phase (KW)291
Maximum power three phase (KVA)400
Continuous power three phase (KVA)364
FuelDiesel
Frequency (Hz)50
Voltage (V)400
Sockets configurationTerminal box
Engine4 stroke
Emissions RegulationsStage 3A
Engine rpm (rpm)1500
Speed governorMechanical
Number cylinders6
Cylinders' positionIn line
CoolingAir
Poles4
Bore x stroke (mm)91.4x127
Length (mm)3380
Width (mm)1500
Height (mm)2171
Dry weight (Kg)3890
SilencedNo
BrushesNo
Product typeGenerator
Control unitPowerStart 600
ATS Switch deviceOptional
Type of alternatorConstant Speed
Engine manufacturerCummins
Precision of voltage regulation± 2,5%

* The data shown are supplied by the manufacturer, ManelService assumes no responsibility for any incorrect values. Take a look at the attached manufacturer's data sheet.

Details

CUMMINS C400 D5eB Control system

Generator set control PowerStart 600

The PowerStart contol is a microprocessor-based generator set monitoring and control system. The control provides a simple operator interface to the generator set, auto/ manual and remote start/stop control and shutdown fault indication. The integration of all control functions into a single control provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet the harsh environment in which gensets are typically applied.

• The PowerStart generator set control is suitable for use on a wide range of generator sets in nonparalleling applications. It is suitable for use with reconnectable or non-reconnectable generators, can be configured for either 50 Hz or 60 Hz and voltage and power connection from 190-600 VAC line-to-line.

• This control includes an intuitive operator interface that allows for complete genset control as well as system metering, fault annunciation, maintenance alarm, over imbalance current, configuration and diagnostics. The interface includes seven generator set status LED lamps with both internationally accepted symbols and English text to comply with customer needs. The interface also includes an LED backlit LCD display with tactile-feel softswitches for easy operation and screen navigation. The manual/auto/stop switch function is integrated into the interface panel.

• All data on the control can be viewed by scrolling through screens with the navigation keys. The control displays the current active fault and a timeordered history of the five previous faults.

• Power for this control is derived from the generator set starting batteries and functions over a voltage range from 8VDC to 16 VDC.

  • Reviews (0)
  • Be the first to write your review !

    RELATED ACCESSORIES


    spedizioni eng
    pagamenti sicuri eng
    esperienza eng
    certificazioni eng
    PhaseThree phase
    Maximum power three phase (KW)320
    Continuous power three phase (KW)291
    Maximum power three phase (KVA)400
    Continuous power three phase (KVA)364
    FuelDiesel
    Frequency (Hz)50
    Voltage (V)400
    Sockets configurationTerminal box
    Engine4 stroke
    Emissions RegulationsStage 3A
    Engine rpm (rpm)1500
    Speed governorMechanical
    Number cylinders6
    Cylinders' positionIn line
    CoolingAir
    Poles4
    Bore x stroke (mm)91.4x127
    Length (mm)3380
    Width (mm)1500
    Height (mm)2171
    Dry weight (Kg)3890
    SilencedNo
    BrushesNo
    Product typeGenerator
    Control unitPowerStart 600
    ATS Switch deviceOptional
    Type of alternatorConstant Speed
    Engine manufacturerCummins
    Precision of voltage regulation± 2,5%

    CUMMINS C400 D5eB Control system

    Generator set control PowerStart 600

    The PowerStart contol is a microprocessor-based generator set monitoring and control system. The control provides a simple operator interface to the generator set, auto/ manual and remote start/stop control and shutdown fault indication. The integration of all control functions into a single control provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet the harsh environment in which gensets are typically applied.

    • The PowerStart generator set control is suitable for use on a wide range of generator sets in nonparalleling applications. It is suitable for use with reconnectable or non-reconnectable generators, can be configured for either 50 Hz or 60 Hz and voltage and power connection from 190-600 VAC line-to-line.

    • This control includes an intuitive operator interface that allows for complete genset control as well as system metering, fault annunciation, maintenance alarm, over imbalance current, configuration and diagnostics. The interface includes seven generator set status LED lamps with both internationally accepted symbols and English text to comply with customer needs. The interface also includes an LED backlit LCD display with tactile-feel softswitches for easy operation and screen navigation. The manual/auto/stop switch function is integrated into the interface panel.

    • All data on the control can be viewed by scrolling through screens with the navigation keys. The control displays the current active fault and a timeordered history of the five previous faults.

    • Power for this control is derived from the generator set starting batteries and functions over a voltage range from 8VDC to 16 VDC.

    Be the first to write your review !

    RELATED PRODUCTS